0102030405
1200V 2-Pole Type 2 SPD Surge Protection Device for PV Systems - China Suppliers and Factory, 20-40kA
01
Model Meaning
02
Product principle and working conditions
- Meets ClassⅡ (8/20μs) SPD tests
- Based on zinc oxide technology
- Using 34S MOV, the maximum will be up to 8/20μs 40kA
- No power frequency continuous flow
- The operating environment temperature is -40°C~+80°C
- Remote signaling function is optional.
- When product falls, the green window turns to red and remote signaling provides remote alarm function
03
Technical parameter details
| Parameter | Specifications | ||||
|---|---|---|---|---|---|
| POLE | 2P/2+0 | ||||
| Technology | MOV(Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE/N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220v | 300V | 380V | 400V | 225V |
| Max.continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current(8/20μs) [In] | 20kA | 20kA | |||
| Max.discharge current (8/20μs) [lmax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | - | |||
| Temporary overvoltage(TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [lsccr] | 25kA | ||||
| Max, backup fuse | 63AgL/Gg | ||||
04
Mechanical Data
| Mechanical Parameters | |
|---|---|
| Current | AC system |
| SPD configuration | Single/Three phase |
| Pluggable | Available |
| Mounting | 35mm DlN rail |
| Housing material | Thermoplastic,UL 94 V-O |
| Operating temperature | -40℃...+80℃ |
| Protection rating | IP20 |
| Remote Signaling | Green/Red |
| Wiring for remote signaling | Optional |
| Max.Voltage/Current for remote signaling | Max 1.5mm solid/flexible |
| Standards compliance | 250V/0.1A;125V/0.2A;75V/0.5A |
| Certification | CE,CB,RoHS,TUV |
05
Outer appearance and installation dimensions
They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of "Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.
06
Installation considerations
- 1. Before installation, ensure power is disconnected. Operating while energized is strictly prohibited.
- 2. It is recommended to install a fuse or circuit breaker in series at the front end of the surge protection module.
- 3. Follow the installation diagram for connection during installation. DC+ is the positive pole, DC- is the negative pole, and PE is the ground wire. Avoid incorrect connections. After installation, close the circuit breaker (or fuse) switch and check if the operation status is normal.
- 4. After installation, insert the module into place and verify if the surge protection module is functioning correctly.
- 5. During use, regularly inspect the surge protection module and check the status of the fault display window. If the fault display window turns red or if the remote signaling terminal outputs an alarm signal, it indicates a malfunction of the surge protection module, which should be promptly repaired or replaced.
- 6. Parallel-connected power surge protection modules should be installed in parallel. The connection wires must be secure, reliable, short, thick, and straight.
Frequently Asked Questions
What is the operating temperature range for this SPD?
The operating environment temperature range for this surge protection module is -40°C to +80°C.
How do I know if the surge protection module has failed?
Regularly check the status of the fault display window. If the window turns red or if the optional remote signaling terminal outputs an alarm signal, the module has malfunctioned and should be promptly repaired or replaced.
What technology is this surge protection device based on?
This device is based on zinc oxide technology, utilizing 34S MOV (Metal Oxide Varistors) and GDT (Gas Discharge Tube) components to achieve protection modes L-PE, N-PE, and NPE.
What are the installation requirements for wiring?
During installation, follow the diagram: connect DC+ to the positive pole, DC- to the negative pole, and PE to the ground. Ensure that the parallel-connected wires are secure, reliable, short, thick, and straight.
Does the product support pluggable modules and remote signaling?
Yes, the module is pluggable and mountable on a 35mm DIN rail. The remote signaling function is optional, providing a remote alarm when the indicator turns from green to red.