1500V 3P T2 Surge Protection Device for Air Conditioners | China Suppliers Factory - LKX-PV 20-40kA Performance
Model Meaning
Product principle and working conditions
- Meets ClassⅡ (8/20μs) SPD tests
- Based on zinc oxide technology
- Using 34S MOV, the maximum will be up to 8/20μs 40kA
- No power frequency continuous flow
- The operating environment temperature is -40°C~+80°C
- Remote signaling function is optional.
- When product falls, the green window turns to red and remote signaling provides remote alarm function
Technical parameter details
| Technical Data | ||||
| POLE | 3P | |||
| SPD Type | Type 2/ClassⅡ | |||
| Technology | MOV/MOV+GDT | |||
| Protection mode(s) | DC+PE.DC | |||
| Max.continuous operating voltage (D.c.) [Ucpv] | 800V | 1000V | 1200V | 1500V |
| Nominal discharge current(8/20μs) [In] | 20kA | |||
| Max.discharge current (8/20μs) [lmax] | 40kA | |||
| Protection level [Up] | ≤3.6kV | ≤4.0kV | ≤4.5kV | ≤5.2kV |
| Response time [tA] | ≤25ns | |||
| Admissible short-circuit current [lsccr] | 25kA | |||
| Max, backup fuse | 125AgL/Gg | |||
Mechanical Data
| Mechanical Data | ||||
| Current | AC system | |||
| SPD configuration | Single/Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DIN rail | |||
| Housing material | Thermoplastic,UL 94 V-O | |||
| Operating temperature | -40℃...+80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green/Red | |||
| Wiring for remote signaling | Optional | |||
| Max.Voltage/Current for remote signaling | Max 1.5mm solid/flexible | |||
| Standards compliance | 250V/0.1A;125V/0.2A;75V/0.5A | |||
| Certification | CE,CB,RoHS,TUV | |||
Outer appearance and installation dimensions
Installation considerations
- 1. Before installation, ensure power is disconnected. Operating while energized is strictly prohibited.
- 2. It is recommended to install a fuse or circuit breaker in series at the front end of the surge protection module.
- 3. Follow the installation diagram for connection during installation. DC+ is the positive pole, DC- is the negative pole, and PE is the ground wire. Avoid incorrect connections. After installation, close the circuit breaker (or fuse) switch and check if the operation status is normal.
- 4. After installation, insert the module into place and verify if the surge protection module is functioning correctly.
- 5. During use, regularly inspect the surge protection module and check the status of the fault display window. If the fault display window turns red or if the remote signaling terminal outputs an alarm signal, it indicates a malfunction of the surge protection module, which should be promptly repaired or replaced.
- 6. Parallel-connected power surge protection modules should be installed in parallel. The connection wires must be secure, reliable, short, thick, and straight.
Frequently Asked Questions (FAQ)
What is the maximum discharge current (Imax) for this SPD?
The maximum discharge current (Imax) for this surge protection device is 40kA (8/20μs), with a nominal discharge current (In) of 20kA.
What happens when the surge protection module fails?
The local indicator window will turn from green to red. If you have the optional remote signaling function installed, it will send an alarm signal for remote monitoring.
What is the operating temperature range for this device?
This surge protector is designed to operate reliably in harsh environments with temperatures ranging from -40°C to +80°C.
How should the wiring be connected during installation?
Always follow the installation diagram: DC+ must be connected to the positive pole, DC- to the negative pole, and PE to the ground wire. Ensure all connections are secure, short, thick, and straight.
What standard certifications does this product comply with?
This surge protection device complies with CE, CB, RoHS, and TUV standards, ensuring safety, quality, and environmental compliance.