275V AC 3-Phase T2 SPD Surge Protection Device | LKX-C40 | China Suppliers & Factory for Reliable Protection
⚡ 1. Product Overview
The LKX-C40 is a Type 2 Surge Protective Device (SPD) designed for 275V AC, 3-phase power distribution systems. Built with high-duty MOV components, it provides reliable protection against transient overvoltages caused by switching operations, indirect lightning, and industrial electrical disturbances.
Ideal for industrial and commercial distribution cabinets, the LKX-C40 ensures safer operation of electrical equipment and supports OEM customization, making it suitable for system integrators, panel builders, and electrical solution providers.
⭐ 2. Key Features & Benefits
- Type 2 SPD for AC low-voltage distribution systems
- Nominal discharge current (In): 20kA (8/20 μs)
- Maximum discharge current (Imax): 40kA (8/20 μs)
- Stable 275V AC operating voltage for 3-phase systems
- Pluggable module design for quick replacement & maintenance
- Visual status indicator (Green / Red) for real-time monitoring
- Optional remote signaling contact for system alarm integration
- Fast response time ≤25 ns, protecting sensitive equipment
- Made with UL94-V0 flame-retardant material
- DIN-rail mounting, ideal for OEM integration
- Suitable for industrial plants, commercial buildings, control panels
🏭 3. Applications
The LKX-C40 is designed for a wide range of industrial and commercial power distribution environments, including:
- Industrial distribution cabinets
- Commercial electrical switchboards
- Building power protection systems
- HVAC & automation control panels
- Low-voltage distribution networks
- OEM power system assemblies
📋 4. Technical Specifications
| Technical Data | |||||
|---|---|---|---|---|---|
| POLE | 2P/2+0, 3P/3+0 | ||||
| Technology | MOV (Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE / N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220V | 300V | 380V | 400V | 225V |
| Max. continuous operating voltage (A.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current (8/20μs) [In] | 20kA | 20kA | |||
| Max. discharge current (8/20μs) [Imax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | - | |||
| Temporary overvoltage (TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [Isccr] | 25kA | ||||
| Max. backup fuse | 63AgL/Gg | ||||
| Mechanical Data | |
|---|---|
| Current | AC system |
| SPD configuration | Single / Three phase |
| Pluggable | Available |
| Mounting | 35mm DIN rail |
| Housing material | Thermoplastic, UL 94 V-0 |
| Operating temperature | -40℃...+80℃ |
| Protection rating | IP20 |
| Remote Signaling | Green / Red |
| Wiring for remote signaling | Optional |
| Max. Voltage/Current for remote signaling | Max 1.5mm² solid/flexible |
| Standards compliance | 250V/0.1A; 125V/0.2A; 75V/0.5A |
| Certification | CE, CB, RoHS, TUV |
🔧 5. Installation & Operating Conditions
For optimal safety and performance:
- Install on a 35mm DIN rail inside distribution cabinets
- Ensure correct wiring: L / N / PE for 3-phase AC systems
- Recommended to be installed by qualified electricians
- Use appropriate backup protection (e.g., 63A gG fuse)
- Ensure grounding resistance meets local electrical standards
- Operating temperature: –40°C to +80°C
- Indoor installation is recommended for stable performance
- Replace the pluggable protection module if the indicator turns red
This information helps ensure correct installation and builds professional trust for OEM clients.
✉️ 6. Call to Action
Looking for a reliable OEM surge protection solution for industrial and commercial power systems?
Need custom branding, large-batch OEM, or technical support?
👉 Contact us today for quotations, samples, or OEM cooperation!
We reply fast and support global shipments.
❓ Frequently Asked Questions (FAQ)
💡 What is the main application of the LKX-C40 surge protective device?
The LKX-C40 is designed for low-voltage power distribution systems, specifically protecting industrial distribution cabinets, commercial switchboards, HVAC systems, and control panels from transient overvoltages.
💡 How do I know when the LKX-C40 module needs to be replaced?
The device features a visual status window. A green indicator means the device is operating normally, while a red indicator indicates that the surge protection module has deteriorated and must be replaced.
💡 What are the nominal and maximum discharge currents of this SPD?
The nominal discharge current (In) is 20kA (8/20 μs), and the maximum discharge current (Imax) is 40kA (8/20 μs), offering robust protection against sudden electrical surges.
💡 Does the LKX-C40 support remote status monitoring?
Yes, it comes with an optional remote signaling contact, allowing system operators to integrate the SPD into remote alarm systems for real-time monitoring.
💡 Is the LKX-C40 easy to maintain and install?
Yes, it features a pluggable module design that allows for quick replacement without disconnecting the wiring, and it mounts easily on a standard 35mm DIN rail.