275V AC 3-Pole Surge Protective Device LKX-T1T2-AC | China Suppliers & Factory for Industrial & Commercial Use
Product Summary
LKX-B+C 275V 10kA is for installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage. Applied in modular SPD Class I+II (Class B+C) for various power supply system single-pole protection module. Designed according to IEC 61643-11/EN 61643-11/GB18802.11.
Highlight Features
Technical Data
| Type | LKX-B+C 275V 10kA |
| Rated voltage (max. continuous voltage) [Uc] | 275V AC |
| Lightning impulse current (10/350) [Iimp] | 10kA |
| Nominal discharge current (8/20) [In] | 20kA |
| Max. discharge current (8/20) [Imax] | 40kA |
| Voltage protection level at In [Up] | ≤ 1.5 kV |
| Response time [tA] | ≤ 25ns |
| TOV voltage | 335V/5sec |
| Max. back up fuse [L] | 200A gL/gG |
| Max. back up fuse [L-L’] | 125A gL/gG |
| Operating temperature range [Tu] | -40°C...+80°C |
| Cross-sectional area | 35mm² solid / 50mm² flexible |
| Mounting on | 35mm DIN rail |
| Enclosure material | Light grey thermoplastic, UL94-V0 |
| Dimension | 2 mods (36mm) |
| Test standards | IEC 61643-11; EN 61643-11; GB18802.11 |
| Certification | CE (LVD, EMC); ISO |
| Type of remote signalling contact | Switching contact |
| Switching capacity | AC: 250V/0.5A; DC: 250V/0.1A; 150V/0.2A; 750V/0.5A |
| Cross-sectional area for remote signalling contact | Max. 1.5mm² solid / flexible |
| Packing unit | 1 pc(s) |
Installation Diagram & Overview
275V T1+T2 3P AC Surge Protective Device for 3-Phase Power Systems
This surge protection device is engineered for 3-phase AC power distribution systems and integrates both Type 1 and Type 2 protection in a single unit. It safely discharges direct lightning strikes (10/350 μs waveform) and shields electrical systems from induced or switching surges (8/20 μs waveform). With a continuous operating voltage of 275V AC, it's an ideal choice for main distribution panels in commercial facilities, factories, and other high-risk environments.
Perfect for:
Frequently Asked Questions (FAQ)
Q: What does Class I+II (T1+T2 / Class B+C) combined protection mean?
A: It combines high-energy direct lightning current protection (10/350 μs waveform, Iimp 10kA) and fine surge overvoltage protection (8/20 μs waveform, In 20kA / Imax 40kA) within a single modular unit, eliminating the need for coordinated separate devices.
Q: Where should the LKX-B+C 275V 10kA surge arrester be installed?
A: It is designed for installation at lightning protection zones LPZ 0A-1 or higher, typically mounted directly onto 35mm DIN rails in main electrical distribution panels and switchboards.
Q: How do the fault indication window and remote alarm function work?
A: The visual inspection window turns from normal to red when a fault occurs due to thermal disconnection. Simultaneously, the built-in remote switching contact triggers an external alarm signal to monitor status remotely.
Q: What conductor sizes are supported for wiring?
A: The main terminals support up to 35mm² solid conductors or 50mm² flexible conductors with multifunctional connection options for busbars and cables. The remote signalling port supports wires up to 1.5mm².
Q: What backup fuse specifications are required for safe operation?
A: The maximum backup fuse rating is 200A gL/gG for standard line connection [L], and 125A gL/gG for series V-shape configuration [L-L'].
Q: What international standards and certifications does this unit comply with?
A: The device is fully compliant with IEC 61643-11, EN 61643-11, and GB18802.11 standards, and is CE (LVD, EMC) and ISO certified.