The **Type 1+2 SPD Surge Protective Device 25kA 275V AC 3-Pole (LKX-T1T2-AC)** is an advanced surge protection solution designed for low-voltage power systems, providing exceptional **Class I + Class II lightning and surge protection**. This device is capable of effectively managing direct lightning currents, transient overvoltage, and switching surges. Utilizing innovative **GDT + high-performance MOV hybrid technology**, it ensures a rapid response, high discharge capacity, and thermal disconnector safety. This results in stable long-term operation, making it ideal for **main switchboards, distribution panels, commercial buildings, industrial equipment, and 275V AC power networks**. As a leading manufacturer and supplier based in China, our factory is committed to delivering high-quality surge protection devices that meet international standards

    Summary
    LKX-B+C 275V 10kA is for installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage. Applied in modular SPD Class I+II (Class B+C) for various power supply system single-pole protection module. Designed according to IEC 61643-11/EN 61643-11/GB18802.11.
    Highlight Features
    • 10/350, 8/20us varistor; Lightning impulse current to Iimp 10kA.
    • Three-poles high discharge capacity surge arrester.
    • Consist of varistors and thermal disconnection devices.
    • Double terminal for parallel or series (V-shape) connection.
    • Multifunctional connection for conductors and busbar.
    • Windows will change to red when fault and also provide remote alarm control at the same time.
    Technical Data
    Type LKX-B+C 275V 10kA
    Rated voltage (max. continuous voltage) [Uc] 275V AC
    Lightning impulse current (10/350) [Iimp] 10kA
    Nominal discharge current (8/20) [In] 20kA
    Max. discharge current (8/20) [Imax] 40kA
    Voltage protection level at In [Up] ≤ 1.5kV
    Response time [tA] ≤ 25ns
    TOV voltage 335V/5sec
    Max. back up fuse [L] 200A gL/gG
    Max. back up fuse [L-L’] 125A gL/gG
    Operating temperature range [Tu] -40°C...+80°C
    Cross-sectional area 35mm² solid / 50mm² flexible
    Mounting on 35mm DIN rail
    Enclosure material Light grey thermoplastic, UL94-V0
    Dimension 2 mods (36mm)
    Test standards IEC 61643-11; EN 61643-11; GB18802.11
    Certification CE (LVD, EMC); ISO
    Type of remote signalling contact Switching contact
    Switching capacity AC:250V/0.5A; DC:250V/0.1A; 150V/0.2A; 750V/0.5A
    Cross-sectional area for remote signalling contact Max. 1.5mm² solid / flexible
    Packing unit 1pc(s)
    Installation Diagram
    spd ac, SOLAR Spd, lightning protection system.png
    AC SPD, surge protective device, T1+T2 SPD 3P.jpg
    275V T1+T2 3P AC Surge Protective Device for 3-Phase Power Systems
    This surge protection device is engineered for 3-phase AC power distribution systems and integrates both Type 1 and Type 2 protection in a single unit. It safely discharges direct lightning strikes (10/350 μs waveform) and shields electrical systems from induced or switching surges (8/20 μs waveform). With a continuous operating voltage of 275V AC, it's an ideal choice for main distribution panels in commercial facilities, factories, and other high-risk environments.
    Perfect for:
    • ✔️ Three-phase surge protection
    • ✔️ Main switchboard lightning protection
    • ✔️ 275V AC power supply systems
    • ✔️ T1+T2 combined SPD for industrial applications
    • ✔️ High-energy surge protection device for commercial buildings
    • ✔️ DIN rail mounted SPD for distribution boards
    • ✔️ AC surge suppressor for lightning-prone areas
    Frequently Asked Questions
    What is the main application of the LKX-B+C 275V 10kA SPD?

    This device is designed for installation at LPZ 0A-1 boundaries or higher. It acts as a Class I+II (Class B+C) combined surge protective device, protecting low-voltage electrical equipment from transient overvoltages and lightning surges.

    How does the visual fault indicator work on this device?

    The device features local inspection windows. When a fault occurs or the module is degraded, the window changes from green to red. It also features remote alarm contacts to alert operators of system faults simultaneously.

    What certifications and testing standards does this product meet?

    The LKX-B+C is fully designed and certified in accordance with international standards IEC 61643-11, EN 61643-11, and GB18802.11, and holds CE (LVD, EMC) and ISO certifications.

    What type of wiring connections does this SPD support?

    It features double terminals for parallel or series (V-shape) connection, offering a multifunctional connection interface suitable for both standard conductors and busbars.

    What is the difference between the Iimp and In ratings on this SPD?

    The Iimp (10kA) measures the direct lightning impulse current handling capability using a 10/350 μs waveform, while the In (20kA) measures the nominal discharge current handling capability using an 8/20 μs waveform for induced surges.