320V 2P Type 2 Surge Protection Device LKX-C40 - China Suppliers Factory for Reliable AC Protection
Product principle and working conditions
- Meets Class II (8/20 μs) SPD tests.
- Based on Zinc Oxide Technology.
- Using 34S MOV, the maximum is up to 8/20μs 40kA.
- No power frequency, continuous flow.
- Compact, yet high surge rated pluggable design, with a minimum 35mm DIN rail width.
- The operational temperature range is -40℃ to +80℃.
- For remote monitoring, red/green status indication and changeover contacts are standard. (Remote function is optional).
Technical parameter details
| Technical Data | |||||
| POLE | 2P/2+0 | ||||
| Technology | MOV(Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE/N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220V | 300V | 380V | 400V | 225V |
| Max.continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current(8/20μs) [In] | 20kA | 20kA | |||
| Max.discharge current (8/20μs) [lmax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | ||||
| Temporary overvoltage(TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [lsccr] | 25kA | ||||
| Max, backup fuse | 63AgL/Gg | ||||
Mechanical Data
| Mechanical Data | ||||
| Current | AC system | |||
| SPD configuration | Single/Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DIN rail | |||
| Housing material | Thermoplastic,UL 94 V-O | |||
| Operating temperature | -40℃...+80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green/Red | |||
| Wiring for remote signaling | Optional | |||
| Max.Voltage/Current for remote signaling | Max 1.5mm solid/flexible | |||
| Standards compliance | 250V/0.1A;125V/0.2A;75V/0.5A | |||
| Certification | CE, CB, RoHS,TUV | |||
Outer appearance and installation dimensions
Installation considerations
-
1
Be sure to turn off the power before beginning the installation. Operating when energized is strictly banned.
-
2
A fuse or circuit breaker should be installed in series at the front of the surge protection module.
-
3
Connect according to the installation diagram throughout the installation process. Avoid making improper connections. After installation, close the circuit breaker (or fuse) switch and ensure that the operation is OK.
-
4
After installation, insert the module and check that the surge protection module is working properly.
-
5
During operation, inspect the surge protection module on a regular basis and monitor the state of the fault display window. If the fault display window turns red or the remote signaling terminal emits an alarm signal, it indicates that the surge protection module is malfunctioning and should be repaired or replaced immediately.
-
6
Install power surge protection units in parallel. The connection wires must be sturdy, dependable, short, thick, and straight.
Frequently Asked Questions (FAQ)
What is the core technology and capacity of this surge protection device?
The device is based on Zinc Oxide Technology. It utilizes a 34S MOV, allowing for a maximum discharge current (8/20μs) of up to 40kA with no power frequency continuous flow.
What is the operating temperature range for this module?
The operational temperature range for the surge protection module is designed to withstand extreme conditions from -40℃ to +80℃.
How do I mount this surge protection device?
It features a compact, pluggable design compatible with standard 35mm DIN rails for easy and secure installation.
How do I know if the surge protection module is malfunctioning?
During regular inspections, check the state of the fault display window. If the window turns red or the remote signaling terminal triggers an alarm, the module is malfunctioning and must be replaced immediately.
What safety precautions should be taken during installation?
You must turn off the power before starting the installation. Additionally, a fuse or circuit breaker must be installed in series at the front of the module, and connection wires must be kept short, thick, straight, and sturdy.