320V 2P Type 2 Surge Protection Device LKX-C40 - China Suppliers & Factory for Reliable Surge Protection
Product Principle and Working Conditions
- Meets Class II (8/20 μs) SPD tests.
- Based on Zinc Oxide Technology.
- Using 34S MOV, the maximum is up to 8/20μs 40kA.
- No power frequency, continuous flow.
- Compact, yet high surge rated pluggable design, with a minimum 35mm DIN rail width.
- The operational temperature range is -40℃ to +80℃.
- For remote monitoring, red/green status indication and changeover contacts are standard (Remote function is optional).
Technical Parameter Details
| Technical Data | |||||
|---|---|---|---|---|---|
| POLE | 2P/2+0 | ||||
| Technology | MOV (Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE/N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220V | 300V | 380V | 400V | 225V |
| Max. continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current (8/20μs) [In] | 20kA | 20kA | |||
| Max. discharge current (8/20μs) [lmax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | - | |||
| Temporary overvoltage (TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [lsccr] | 25kA | ||||
| Max. backup fuse | 63AgL/Gg | ||||
Mechanical Data
| Mechanical Data | ||||
|---|---|---|---|---|
| Current | AC system | |||
| SPD configuration | Single/Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DIN rail | |||
| Housing material | Thermoplastic, UL 94 V-O | |||
| Operating temperature | -40℃ ... +80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green/Red | |||
| Wiring for remote signaling | Optional | |||
| Max. Voltage/Current for remote signaling | Max 1.5mm solid/flexible | |||
| Standards compliance | 250V/0.1A; 125V/0.2A; 75V/0.5A | |||
| Certification | CE, CB, RoHS, TUV | |||
Outer Appearance and Installation Dimensions
Installation Considerations
- Be sure to turn off the power before beginning the installation. Operating when energized is strictly banned.
- A fuse or circuit breaker should be installed in series at the front of the surge protection module.
- Connect according to the installation diagram throughout the installation process. Avoid making improper connections. After installation, close the circuit breaker (or fuse) switch and ensure that the operation is OK.
- After installation, insert the module and check that the surge protection module is working properly.
- During operation, inspect the surge protection module on a regular basis and monitor the state of the fault display window. If the fault display window turns red or the remote signaling terminal emits an alarm signal, it indicates that the surge protection module is malfunctioning and should be repaired or replaced immediately.
- Install power surge protection units in parallel. The connection wires must be sturdy, dependable, short, thick, and straight.
Frequently Asked Questions (FAQ)
What technology is this Surge Protection Device (SPD) based on?
This surge protection device is designed based on high-performance Zinc Oxide Technology and uses 34S Metal Oxide Varistors (MOV).
What is the maximum discharge current (Imax) for this device?
The maximum discharge current (8/20μs) [Imax] of this surge protection device is up to 40kA.
What is the operational temperature range for this SPD?
This device is designed to operate reliably in ambient temperatures ranging from -40℃ to +80℃.
Does it support remote monitoring functions?
Yes, red/green status indication and changeover contacts are standard features for remote monitoring. The remote signaling function is optional.
What certifications does this surge protector comply with?
The product complies with international quality and safety standards, holding CE, CB, RoHS, and TUV certifications.
What should I do if the fault display window turns red?