Leave Your Message
China LKX-PV Series Surge Protectors SPD for Solar & Wind Power - Trusted Suppliers & Factory
Hot Products

China LKX-PV Series Surge Protectors SPD for Solar & Wind Power - Trusted Suppliers & Factory

The LKX-PV series surge protective devices (SPDs) are specifically designed for new energy wind and solar power generation systems, available in operating voltages of 500V, 800V, and 1000V. Manufactured in China, these advanced protectors are essential components in your primary DC power system, offering robust protection against transient overvoltages, including both indirect and direct lightning currents. As a leading supplier and factory in the industry, we ensure that our products meet the highest standards for safety and reliability in renewable energy applications. Protect your investment in clean energy with our reliable LKX-PV series SPDs.

    01

    Model Meaning

    Model Meaning Diagram
    02

    Characteristics of the Product

    • ✔ 1. Plug-in design Surge Protective Device (SPDs)
    • ✔ 2. The visual window indicates the working status of the SPD, green (normal), red (replace)
    • ✔ 3. Dual protection of hot melt overcurrent
    • ✔ 4. Configure telecontrol interface to achieve remote control
    03

    Technical Parameter Details

    Product name 48V DC SPD 500V DC SPD 600V DC SPD 800V DC SPD 1000V DC SPD 1500V DC SPD
    Product model LKX-PV-48V LKX-PV-500V LKX-PV-600V LKX-PV-800V LKX-PV-1000V LKX-PV-1500V
    In (kA) 20 20 20 20 20 20
    Imax (kA) 40 40 40 40 40 40
    Up (kV) 1.0 2.5 3.2 3.6 4.0 5.2
    Response time (μs) 25 25 25 25 25 25
    Uc 48V 500V 600V 800V 1000V 1500V
    Operating temperature -40~+85℃ -40~+85℃ -40~+85℃ -40~+85℃ -40~+85℃ -40~+85℃
    04

    Outer Appearance and Installation Dimensions

    Appearance and Dimension 1
    Appearance and Dimension 2
    Appearance and Dimension 3
    Appearance and Dimension 4
    05

    Installation Considerations

    • ⚠ 1. Before installation, ensure power is disconnected. Operating while energized is strictly prohibited.
    • ⚠ 2. It is recommended to install a fuse or circuit breaker in series at the front end of the surge protection module.
    • ⚠ 3. Follow the installation diagram for connection during installation. DC+ is the positive pole, DC- is the negative pole, and PE is the ground wire. Avoid incorrect connections. After installation, close the circuit breaker (or fuse) switch and check if the operation status is normal.
    • ⚠ 4. After installation, insert the module into place and verify if the surge protection module is functioning correctly.
    • ⚠ 5. During use, regularly inspect the surge protection module and check the status of the fault display window. If the fault display window turns red or if the remote signaling terminal outputs an alarm signal, it indicates a malfunction of the surge protection module, which should be promptly repaired or replaced.
    • ⚠ 6. Parallel-connected power surge protection modules should be installed in parallel. The connection wires must be secure, reliable, short, thick, and straight.

    ❓ Frequently Asked Questions (FAQ)

    Q1: What does the status window on the SPD indicate?

    The visual indicator window shows the real-time operational status of the device. Green indicates the SPD is working normally, while red signals a fault or expiration, meaning the module must be replaced immediately.

    Q2: Can the surge protective module be replaced without cutting power?

    Thanks to the plug-in module design, maintenance is convenient. However, for total electrical safety and adhering to guidelines, disconnecting upstream power before any installation or replacement is always recommended.

    Q3: Why is a fuse or circuit breaker needed before the SPD?

    Installing a backup fuse or circuit breaker in series protects the system from thermal runaway or continuous short-circuit currents in case the SPD reaches the end of its life cycle or encounters extreme overload.

    Q4: How does the remote telecontrol interface work?

    The remote signaling interface features dry contacts that connect to external monitoring systems or alarms. It automatically triggers an alert if the SPD degrades or trips, enabling centralized monitoring.

    Q5: Why must connection wires be short, thick, and straight?

    High-frequency surge currents face significant impedance from long or looped cables. Keeping wires short, thick, and straight minimizes inductive voltage drops across the wiring, ensuring optimal surge suppression and faster response.

    Q6: What voltage ratings are available for this series?

    The LKX-PV DC series supports multiple maximum continuous operating voltages (Uc), including 48V, 500V, 600V, 800V, 1000V, and up to 1500V DC applications.