Leave Your Message
China Suppliers Factory Industrial Surge Protective Device 275V AC 3-Pole Type 1+2 SPD 25kA Lightning Protection
Hot Products

China Suppliers Factory Industrial Surge Protective Device 275V AC 3-Pole Type 1+2 SPD 25kA Lightning Protection

The **Type 1+2 SPD Surge Protective Device 25kA 275V AC 3-Pole (LKX-T1T2-AC)** is a cutting-edge solution designed for optimal lightning and surge protection in low-voltage power systems. Offering combined **Class I + Class II** protection, this device effectively manages direct lightning currents, transient overvoltage, and switching surges. Engineered with advanced **GDT + high-performance MOV hybrid technology**, it ensures rapid response times, a high discharge capacity, and enhanced safety with its thermal disconnector features. This robust device is ideal for a variety of applications, including main switchboards, distribution panels, commercial buildings, industrial equipment, and 275V AC power networks. As a leading **China supplier**, we are committed to delivering high-quality surge protection solutions directly from our factory to meet your specific needs

    Summary

    LKX-B+C 275V 10kA is for installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage. Applied in modular SPD Class I+II (Class B+C) for various power supply system single-pole protection module. Designed according to IEC 61643-11/EN 61643-11/GB18802.11.

    Highlight Features
    • 10/350, 8/20us varistor; Lightning impulse current to Iimp 10kA.
    • Three-poles high discharge capacity surge arrester.
    • Consist of varistors and thermal disconnection devices.
    • Double terminal for parallel or series (V-shape) connection.
    • Multifunctional connection for conductors and busbar.
    • Windows will change to red when fault and also provide remote alarm control at the same time.
    Technical Data
    Type LKX-B+C 275V 10kA
    Rated voltage (max. continuous voltage) [Uc] 275V AC
    Lightning impulse current (10/350) [Iimp] 10kA
    Nominal discharge current (8/20) [In] 20kA
    Max. discharge current (8/20) [Imax] 40kA
    Voltage protection level at In [Up] ≤ 1.5kV
    Response time [tA] ≤ 25ns
    TOV voltage 335V/5sec
    Max. back up fuse [L] 200A gL/gG
    Max. back up fuse [L-L’] 125A gL/gG
    Operating temperature range [Tu] -40°C...+80°C
    Cross-sectional area 35mm² solid / 50mm² flexible
    Mounting on 35mm DIN rail
    Enclosure material Light grey thermoplastic, UL94-V0
    Dimension 2 mods (36mm)
    Test standards IEC 61643-11; EN 61643-11; GB18802.11
    Certification CE (LVD, EMC); ISO
    Type of remote signalling contact Switching contact
    Switching capacity AC:250V/0.5A; DC:250V/0.1A; 150V/0.2A; 750V/0.5A
    Cross-sectional area for remote signalling contact Max. 1.5mm² solid / flexible
    Packing unit 1pc(s)
    Installation Diagram
    275V T1+T2 3P AC Surge Protective Device for 3-Phase Power Systems

    This surge protection device is engineered for 3-phase AC power distribution systems and integrates both Type 1 and Type 2 protection in a single unit. It safely discharges direct lightning strikes (10/350 μs waveform) and shields electrical systems from induced or switching surges (8/20 μs waveform). With a continuous operating voltage of 275V AC, it's an ideal choice for main distribution panels in commercial facilities, factories, and other high-risk environments.

    Perfect for:
    • Three-phase surge protection
    • Main switchboard lightning protection
    • 275V AC power supply systems
    • T1+T2 combined SPD for industrial applications
    • High-energy surge protection device for commercial buildings
    • DIN rail mounted SPD for distribution boards
    • AC surge suppressor for lightning-prone areas
    Frequently Asked Questions

    What is the main application of the LKX-B+C 275V 10kA SPD?

    This device is designed for installation at the boundary of LPZ 0A-1 or higher. It acts as a Class I+II (Class B+C) combined surge protective device, protecting low-voltage electrical equipment and distribution systems from transient overvoltages and direct lightning strikes.

    How does the visual fault indicator window work?

    Under normal operating conditions, the status window remains green (or clear). If a fault occurs or the module degrades due to high-energy surges, the window will change to red, indicating that replacement is required. It also triggers the remote alarm signaling contact simultaneously.

    What standards does this surge protection device comply with?

    The LKX-B+C 275V 10kA is designed, tested, and certified in strict compliance with international standards including IEC 61643-11, EN 61643-11, and the national standard GB18802.11.

    Can this device be used for 3-phase AC power systems?

    Yes, this combined T1+T2 SPD is designed to protect standard 3-phase AC power distribution systems against both high-energy lightning impulse currents and transient switching surges.

    What type of mounting does the unit support?

    The unit features a standard DIN rail mounting design compatible with all standard 35mm DIN rails, making it quick and easy to install inside standard distribution boards and switchgear panels.