China Suppliers Factory Type 2 SPD Surge Protection Device 1000V 3-Pole for Photovoltaic & DC Power Systems

The **Type 2 SPD Surge Protective Device 20–40kA 1000V DC 3-Pole (LKX-PV)** is an essential solution for robust Class II surge protection in **high-voltage photovoltaic and DC power systems**. This device effectively mitigates transient overvoltage, switching surges, and induced lightning currents. Built with **high-capacity MOV components, thermal disconnector safety, and a fast response design**, it guarantees reliable long-term protection for **large PV arrays, combiner boxes, multi-string inverters, DC distribution cabinets, battery-storage systems, and 1000V DC off-grid or hybrid solar installations**. As a leading **China supplier** and **factory** for surge protection devices, we ensure our products meet the highest standards for safety and reliability

    01

    Model Meaning

    02

    Product Principle and Working Conditions

    • Meets Class II (8/20μs) SPD tests
    • Based on zinc oxide technology
    • Using 34S MOV, the maximum will be up to 8/20 μs 40kA
    • No power frequency continuous flow
    • The operating environment temperature is -40°C ~ +80°C
    • Remote signaling function is optional
    • When product falls, the green window turns to red and remote signaling provides remote alarm function
    03

    Technical Parameter Details

    Technical Data
    POLE 3P
    SPD Type Type 2 / Class II
    Technology MOV / MOV+GDT
    Protection mode(s) DC+PE, DC-PE
    Max. continuous operating voltage (D.c.) [Ucpv] 800V 1000V 1200V 1500V
    Nominal discharge current (8/20μs) [In] 20kA
    Max. discharge current (8/20μs) [Imax] 40kA
    Protection level [Up] ≤3.6kV ≤4.0kV ≤4.5kV ≤5.2kV
    Response time [tA] ≤25ns
    Admissible short-circuit current [Isccr] 25kA
    Max. backup fuse 125A gL/gG
    04

    Mechanical Data

    Mechanical Data
    Current AC system
    SPD configuration Single/Three phase
    Pluggable Available
    Mounting 35mm DIN rail
    Housing material Thermoplastic, UL 94 V-0
    Operating temperature -40°C ... +80°C
    Protection rating IP20
    Remote Signaling Green/Red Indicator
    Wiring for remote signaling Optional
    Max. Voltage/Current for remote signaling Max 1.5mm² solid/flexible
    Standards compliance 250V/0.1A; 125V/0.2A; 75V/0.5A
    Certification CE, CB, RoHS, TUV
    05

    Outer Appearance and Installation Dimensions

    Our professional engineering group will always be ready to serve you for consultation and feedback. We are able to also offer you with absolutely free samples to meet your requirements. Finest efforts will likely be produced to give you the ideal service and goods. For anyone who is thinking about our company and merchandise, please contact us by sending us emails or contact us quickly. As a way to know our merchandise and firm. lot more, you can come to our factory to find out it. We'll always welcome guests from all over the world to our business to build company relations with us. Please feel free to get in touch with us for business and we believe we are going to share the top trading practical experience with all our merchants.
    06

    Installation Considerations

    • Verify complete power de-energization before commencing installation. Any work on active electrical systems is categorically prohibited.
    • For optimal protection, incorporate series-connected overcurrent protection (fuse or breaker) preceding the surge suppression device.
    • Installation wiring must strictly comply with the provided schematic: DC+ = Positive terminal, DC- = Negative terminal, PE = Protective earth ground. Ensure proper terminal identification to prevent wiring errors. Post-installation, energize the system by engaging the protective device and confirm proper operational indicators.
    • Finalize installation by securing the module in its designated location and performing functional validation of the surge protection system.
    • Implement scheduled maintenance inspections including: Visual examination of the diagnostic indicator and verification of alarm contact status. Immediate replacement is mandatory upon detection of red fault indicator illumination or alarm signal activation.
    • Parallel surge protection configurations require: True parallel circuit implementation, properly torqued connections, minimum-length conductors, adequate wire gauge (AWG), and direct routing without unnecessary bends.

    Frequently Asked Questions (FAQ)

    Q1: What is the maximum discharge current (Imax) of this Surge Protective Device?

    The maximum discharge current (Imax) for this device is 40kA (8/20μs) using high-quality 34S MOV technology.

    Q2: How do the local status indicators work, and what do the colors mean?

    The device features a clear visual indicator window. Under normal operating conditions, the window is green. If the device experiences a fault or degradation, the green window turns to red, indicating that immediate replacement is required.

    Q3: What mounting standard is required for this SPD?

    This surge protective device is designed for easy installation and is compatible with standard 35mm DIN rails.

    Q4: Does this device support remote alarm signaling?

    Yes, the remote signaling function is optional. When configured, it provides remote alarm capability when the protection module fails.

    Q5: What is the operating temperature range for this product?

    The device is designed to operate reliably under extreme environmental conditions, with a temperature range of -40°C to +80°C.

    Q6: What certifications does this surge protective device hold?

    This product is fully compliant with international safety and quality standards, holding CE, CB, RoHS, and TUV certifications.