China Suppliers LKX-C40 Type 2 SPD Surge Protection Device 320V AC Factory – 20-40kA Class II Protection
Product Principle and Working Conditions
- Meets Class II (8/20 μs) SPD tests.
- Based on Zinc Oxide Technology.
- Using 34S MOV, the maximum is up to 8/20μs 40kA.
- No power frequency, continuous flow.
- Compact, yet high surge rated pluggable design, with a minimum 35mm DIN rail width.
- The operational temperature range is -40℃ to +80℃.
- For remote monitoring, red/green status indication and changeover contacts are standard (Remote function is optional).
Technical Parameter Details
| Technical Data | |||||
| POLE | 2P/2+0 | ||||
| Technology | MOV (Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE / N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220V | 300V | 380V | 400V | 225V |
| Max. continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current (8/20μs) [In] | 20kA | 20kA | |||
| Max. discharge current (8/20μs) [Imax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | - | |||
| Temporary overvoltage (TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [Isccr] | 25kA | ||||
| Max. backup fuse | 63AgL/gG | ||||
Mechanical Data
| Mechanical Specification Data | ||||
| Current | AC system | |||
| SPD configuration | Single / Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DIN rail | |||
| Housing material | Thermoplastic, UL 94 V-0 | |||
| Operating temperature | -40℃ ... +80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green / Red status indicator | |||
| Wiring for remote signaling | Optional | |||
| Max. Voltage/Current for remote signaling | Max 1.5mm² solid/flexible | |||
| Standards compliance | 250V/0.1A; 125V/0.2A; 75V/0.5A | |||
| Certification | CE, CB, RoHS, TUV | |||
Outer Appearance and Installation Dimensions
Installation Considerations
Frequently Asked Questions (FAQ)
What is the operational temperature range of this surge protective device?
The operational temperature range for this SPD is -40℃ to +80℃, allowing it to function reliably under extreme environmental conditions.
What technology is used in this surge protection module?
This device is built based on Zinc Oxide Technology, utilizing a 34S MOV (Metal Oxide Varistor) to achieve high performance with no power frequency continuous flow.
What is the maximum discharge current (Imax) for this unit?
The maximum discharge current (Imax) for an 8/20μs wave is up to 40kA, meeting Class II SPD test standards.
How do I monitor the status of the surge protection module?
The module features a standard red/green status indication window. Additionally, changeover contacts for remote monitoring signaling are standard, though the remote function itself is optional.
What certifications does this product comply with?
This surge protective device complies with international standards and holds CE, CB, RoHS, and TUV certifications.
What should I do if the fault display window turns red?
A red fault display window or an alarm signal from the remote signaling terminal indicates that the surge protection module is malfunctioning. It must be repaired or replaced immediately.