Product principle and working conditions
1.Meets ClassⅡ (8/20μs) SPD tests
2. Based on zinc oxide technology
3. Using 34S MOV, the maximum will be up to 8/20μs 40kA
4. No power frequency continuous flow
5.The operating environment temperature is -40°C~+80°C
6. Remote signaling function is optional.
7. When product falls, the green window turns to red and remote signaling provides remote alarm function
03
Technical parameter details
| POLE | 2P/2+0 | ||||
| Technology | MOV(Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE/N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220v | 300V | 380V | 400V | 225V |
| Max.continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current(8/20μs) [In] | 20kA | 20kA | |||
| Max.discharge current (8/20μs) [lmax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | ||||
| Temporary overvoltage(TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [lsccr] | 25kA | ||||
| Max, backup fuse | 63AgL/Gg | ||||
04
Mechanical Data
| Mechanical Data | ||||
| Current | AC system | |||
| SPD configuration | Single/Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DlN rail | |||
| Housing material | Thermoplastic,UL 94 V-O | |||
| Operating temperature | -40℃...+80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green/Red | |||
| Wiring for remote signaling | Optional | |||
| Max.Voltage/Current for remote signaling | Max 1.5mm solid/flexible | |||
| Standards compliance | 250V/0.1A;125V/0.2A;75V/0.5A | |||
| Certification | CE,CB,RoHS,TUV | |||
05

Outer appearance and installation dimensions


We solution have passed through the national skilled certification and been well received in our key industry. Our specialist engineering team will often be ready to serve you for consultation and feedback. We are able to also provide you with no cost samples to meet your needs. Best efforts will be produced to offer you the very best service and solutions. For anyone who is considering our business and solutions, please speak to us by sending us emails or get in touch with us right away. As a way to know our products and enterprise. lot more, you'll be able to come to our factory to find out it. We will constantly welcome guests from around the globe to our firm. o build enterprise. elations with us. Please really feel absolutely free to make contact with us for small business and we believe we will share the top trading practical experience with all our merchants.
06
Installation considerations
1. Prior to mounting, verify that electrical supply is isolated. Working on live equipment is absolutely forbidden.
2. A protective fuse or breaker should be serially connected upstream of the lightning arrester unit.
3. Refer to wiring schematics for proper installation. Positive DC connects to DC+, negative to DC-, with PE as earth ground. Prevent reverse polarity. Upon completion, activate the protection device (fuse/breaker) and confirm normal operational indicators.
4. Post-installation, properly seat the component and validate correct functioning of the overvoltage protector.
5. Routine maintenance should include visual inspection of the SPD and monitoring of its diagnostic indicator. Either a red warning display or alarm contact activation denotes device failure requiring immediate replacement.
6. Multi-unit surge suppressors in parallel configuration must maintain true parallel wiring, using minimal-length, large-gauge conductors with secure terminations and straight-line routing.