Leave Your Message
Replaceable Surge Protection Device Module 1200V 3P T2 - China Suppliers & Factory for High-Voltage PV Systems
Hot Products

Replaceable Surge Protection Device Module 1200V 3P T2 - China Suppliers & Factory for High-Voltage PV Systems

,

Introducing the Type 2 SPD Surge Protective Device 20–40kA 1200V DC 3-Pole (LKX-PV), a cutting-edge solution for high-voltage photovoltaic and DC power systems that offers superior Class II surge protection. Engineered to mitigate transient overvoltage, switching surges, and lightning-induced currents, this device is an essential component for ensuring the safety and longevity of your installations. Manufactured in China by trusted suppliers, our device utilizes high-energy MOV modules, thermal disconnection protection, and fast response performance to maintain stability in demanding environments. Ideal for large PV arrays, combiner boxes, multi-string and central inverters, DC distribution cabinets, battery-storage systems, as well as 1200V DC off-grid or hybrid solar installations, our product is a reliable choice for quality, backed by our factory expertise.

,

    01

    Model Meaning

    Model Meaning Diagram
    02

    Characteristics of the Product

    • Meets ClassⅡ (8/20μs) SPD tests
    • Based on zinc oxide technology
    • Using 34S MOV, the maximum will be up to 8/20μs 40kA
    • No power frequency continuous flow
    • The operating environment temperature is -40°C~+80°C
    • Remote signaling function is optional.
    • When product falls, the green window turns to red and remote signaling provides remote alarm function
    03

    Technical parameter details

    Technical Data
    POLE 3P
    SPD Type Type 2/ClassⅡ
    Technology MOV/MOV+GDT
    Protection mode(s) DC+PE.DC
    Max.continuous operating voltage (D.C.) [Ucpv] 800V 1000V 1200V 1500V
    Nominal discharge current(8/20μs) [In] 20kA
    Max.discharge current (8/20μs) [lmax] 40kA
    Protection level [Up] ≤3.6kV ≤4.0kV ≤4.5kV ≤5.2kV
    Response time [tA] ≤25ns
    Admissible short-circuit current [lsccr] 25kA
    Max. backup fuse 125AgL/Gg
    04

    Mechanical Data

    Mechanical Data
    Current AC system
    SPD configuration Single/Three phase
    Pluggable Available
    Mounting 35mm DlN rail
    Housing material Thermoplastic,UL 94 V-O
    Operating temperature -40℃...+80℃
    Protection rating IP20
    Remote Signaling Green/Red
    Wiring for remote signaling Optional
    Max.Voltage/Current for remote signaling Max 1.5mm solid/flexible
    Standards compliance 250V/0.1A;125V/0.2A;75V/0.5A
    Certification CE,CB,RoHS,TUV
    05

    Outer appearance and installation dimensions

    19.Aiming to grow to be by far the most professional supplier within this sector in Uganda, we keep researching on the creating procedure and raising the high quality of our principal goods. Till now, the merchandise list has been updated on a regular basis and attracted customers from around the globe. Detailed data can be obtained in our web page and you'll be served with good quality consultant service by our after-sale team. They're going to allow you to get complete acknowledge about our items and make a satisfied negotiation. Small business check out to our factory in Uganda can also be welcome at any time. Hope to obtain your inquiries to get a happy co-operation.
    20.Our organization. Situated inside the national civilized cities, the visitors is very easy, unique geographical and economic situations. We pursue a "people-oriented, meticulous manufacturing, brainstorm, construct brilliant" organization. hilosophy. Strict top quality management, fantastic service, reasonable cost in Myanmar is our stand on the premise of competition. If vital, welcome to make contact with us by our web page or telephone consultation, we are going to be pleased to serve you.
    06

    Installation considerations

    • Prior to installation, confirm complete power isolation. Any operation under live conditions is expressly forbidden.
    • The surge protector's input side should incorporate an in-line fuse or circuit breaker as protective measure.
    • Adhere strictly to the provided wiring schematic: DC+ denotes positive terminal, DC- indicates negative terminal, and PE represents grounding conductor. Ensure proper polarity during installation. Upon completion, activate the protective device (circuit breaker/fuse) and validate normal operational parameters.
    • Following installation, properly position the unit and conduct functional verification of the surge protective device.
    • Implement periodic maintenance checks on the surge protector, including monitoring of the diagnostic indicator. A red warning display or alarm contact activation signifies device failure requiring immediate attention through repair or replacement.
    • When installing multiple surge protectors in parallel configuration, maintain true parallel wiring with properly secured connections using appropriately sized conductors of minimal length and direct routing.

    Frequently Asked Questions (FAQ)

    Q1: What is the maximum discharge current (Imax) of this surge protective device?

    A1: The maximum discharge current (Imax) for this device is 40kA (8/20μs) using high-quality 34S MOV technology.

    Q2: How do I know if the surge protector has failed and needs replacement?

    A2: The device features a visual diagnostic window. Under normal operations, it displays green. If the window turns red, or the optional remote signaling alarm is triggered, it indicates the device has failed and must be replaced immediately.

    Q3: What is the recommended operating temperature range for this SPD?

    A3: This surge protective device is designed to operate reliably in harsh environments, with an operating temperature range of -40°C to +80°C.

    Q4: Can this device be mounted on standard industrial rails?

    A4: Yes, the unit features a pluggable design compatible with standard 35mm DIN rail mounting for quick and easy installation.

    Q5: Does this surge protector support remote monitoring?

    A5: Yes, remote signaling functionality is optional. When equipped, it provides remote alarm notifications when the device status changes from normal (green) to fault (red).

    Q6: What certifications does this surge protective device hold?

    A6: The product complies with international safety standards and is fully certified by CE, CB, RoHS, and TUV.