Leave Your Message
Replaceable Surge Protection Device Module 1200V 3P T2 | High-Quality China Suppliers & Factory
Hot Products

Replaceable Surge Protection Device Module 1200V 3P T2 | High-Quality China Suppliers & Factory

The **Type 2 SPD Surge Protective Device 20–40kA 1200V DC 3-Pole (LKX-PV)** is an essential solution for robust surge protection in **high-voltage photovoltaic and DC power systems**. As a leading supplier and factory in China, we offer this device to effectively mitigate transient overvoltage, switching surges, and lightning-induced currents. Engineered with **high-energy MOV modules, advanced thermal disconnection protection, and rapid response capabilities**, our surge protective device guarantees long-lasting stability and safety for **large PV arrays, combiner boxes, multi-string and central inverters, DC distribution cabinets, battery-storage systems, and 1200V DC off-grid or hybrid solar installations**. Choose us as your trusted supplier to enhance the reliability of your solar energy systems

    01

    Model Meaning

    02

    Characteristics of the Product

    • Meets ClassⅡ (8/20μs) SPD tests
    • Based on zinc oxide technology
    • Using 34S MOV, the maximum will be up to 8/20μs 40kA
    • No power frequency continuous flow
    • The operating environment temperature is -40°C~+80°C
    • Remote signaling function is optional.
    • When product falls, the green window turns to red and remote signaling provides remote alarm function
    03

    Technical Parameter Details

    Technical Data
    POLE 3P
    SPD Type Type 2/ClassⅡ
    Technology MOV/MOV+GDT
    Protection mode(s) DC+PE.DC
    Max. continuous operating voltage (D.C.) [Ucpv] 800V 1000V 1200V 1500V
    Nominal discharge current (8/20μs) [In] 20kA
    Max. discharge current (8/20μs) [Imax] 40kA
    Protection level [Up] ≤3.6kV ≤4.0kV ≤4.5kV ≤5.2kV
    Response time [tA] ≤25ns
    Admissible short-circuit current [Isccr] 25kA
    Max. backup fuse 125AgL/Gg
    04

    Mechanical Data

    Mechanical Specification
    Current AC system
    SPD configuration Single/Three phase
    Pluggable Available
    Mounting 35mm DIN rail
    Housing material Thermoplastic, UL 94 V-0
    Operating temperature -40℃...+80℃
    Protection rating IP20
    Remote Signaling Green/Red
    Wiring for remote signaling Optional
    Max. Voltage/Current for remote signaling Max 1.5mm solid/flexible
    Standards compliance 250V/0.1A; 125V/0.2A; 75V/0.5A
    Certification CE, CB, RoHS, TUV
    05

    Outer Appearance and Installation Dimensions

    19.Aiming to grow to be by far the most professional supplier within this sector in Uganda, we keep researching on the creating procedure and raising the high quality of our principal goods. Till now, the merchandise list has been updated on a regular basis and attracted customers from around the globe. Detailed data can be obtained in our web page and you'll be served with good quality consultant service by our after-sale team. They're going to allow you to get complete acknowledge about our items and make a satisfied negotiation. Small business check out to our factory in Uganda can also be welcome at any time. Hope to obtain your inquiries to get a happy co-operation.
    20.Our organization. Situated inside the national civilized cities, the visitors is very easy, unique geographical and economic situations. We pursue a "people-oriented, meticulous manufacturing, brainstorm, construct brilliant" organization. hilosophy. Strict top quality management, fantastic service, reasonable cost in Myanmar is our stand on the premise of competition. If vital, welcome to make contact with us by our web page or telephone consultation, we are going to be pleased to serve you.
    06

    Installation Considerations

    • Prior to installation, confirm complete power isolation. Any operation under live conditions is expressly forbidden.
    • The surge protector's input side should incorporate an in-line fuse or circuit breaker as protective measure.
    • Adhere strictly to the provided wiring schematic: DC+ denotes positive terminal, DC- indicates negative terminal, and PE represents grounding conductor. Ensure proper polarity during installation. Upon completion, activate the protective device (circuit breaker/fuse) and validate normal operational parameters.
    • Following installation, properly position the unit and conduct functional verification of the surge protective device.
    • Implement periodic maintenance checks on the surge protector, including monitoring of the diagnostic indicator. A red warning display or alarm contact activation signifies device failure requiring immediate attention through repair or replacement.
    • When installing multiple surge protectors in parallel configuration, maintain true parallel wiring with properly secured connections using appropriately sized conductors of minimal length and direct routing.

    Frequently Asked Questions (FAQ)

    What is the maximum discharge current (Imax) of this SPD?
    The maximum discharge current (Imax) for this surge protective device is up to 40kA (8/20μs) using 34S MOV technology.
    How do I know if the surge protector has failed and needs replacement?
    The device features a visual diagnostic window. When the product is functioning normally, the window is green. If the device fails, the window turns red, and the optional remote signaling function will trigger a remote alarm.
    What is the operating temperature range for this surge protective device?
    The operating environment temperature for this device is rated from -40°C to +80°C, making it suitable for extreme environmental conditions.
    What mounting standard does this device use?
    This surge protective device is designed for easy installation on a standard 35mm DIN rail.
    Is power frequency continuous flow an issue with this SPD?
    No, this device is designed based on advanced zinc oxide technology which ensures there is no power frequency continuous flow during operation.
    What certifications does this product comply with?