Type 2 1000V DC Surge Protection Device 20-40kA | China Suppliers Factory LKX-PV for Solar Systems
Model Meaning
Product Principle and Working Conditions
- Meets ClassⅡ (8/20μs) SPD tests
- Based on zinc oxide technology
- Using 34S MOV, the maximum will be up to 8/20μs 40kA
- No power frequency continuous flow
- The operating environment temperature is -40°C ~ +80°C
- Remote signaling function is optional.
- When product falls, the green window turns to red and remote signaling provides remote alarm function
Technical Parameter Details
| POLE | 2P/2+0 | ||||
| Technology | MOV(Metal Oxide Varistors) | GDT | |||
| Protection mode(s) | L-PE/N-PE | NPE | |||
| Nominal voltage (A.C.) [Un] | 220V | 300V | 380V | 400V | 225V |
| Max. continuous operating voltage (D.C.) [Ucpv] | 275V | 320V | 385V | 420V | 225V |
| Nominal discharge current(8/20μs) [In] | 20kA | 20kA | |||
| Max. discharge current (8/20μs) [lmax] | 40kA | 40kA | |||
| Protection level [Up] | ≤1.5kV | ≤1.6kV | ≤1.8kV | ≤2.0kV | ≤1.5kV |
| Response time [tA] | ≤25ns | ||||
| Temporary overvoltage(TOV) withstand - 5 sec [Ut] | 335V | 440V | 440V | 620V | 335V |
| Admissible short-circuit current [lsccr] | 25kA | ||||
| Max. backup fuse | 63AgL/Gg | ||||
Mechanical Data
| Mechanical Specifications | ||||
|---|---|---|---|---|
| Current | AC system | |||
| SPD configuration | Single/Three phase | |||
| Pluggable | Available | |||
| Mounting | 35mm DIN rail | |||
| Housing material | Thermoplastic, UL 94 V-0 | |||
| Operating temperature | -40℃ ... +80℃ | |||
| Protection rating | IP20 | |||
| Remote Signaling | Green/Red | |||
| Wiring for remote signaling | Optional | |||
| Max. Voltage/Current for remote signaling | Max 1.5mm² solid/flexible | |||
| Standards compliance | 250V/0.1A; 125V/0.2A; 75V/0.5A | |||
| Certification | CE, CB, RoHS, TUV | |||
Outer Appearance and Installation Dimensions
Installation Considerations
- Prior to mounting, verify that electrical supply is isolated. Working on live equipment is absolutely forbidden.
- A protective fuse or breaker should be serially connected upstream of the lightning arrester unit.
- Refer to wiring schematics for proper installation. Positive DC connects to DC+, negative to DC-, with PE as earth ground. Prevent reverse polarity. Upon completion, activate the protection device (fuse/breaker) and confirm normal operational indicators.
- Post-installation, properly seat the component and validate correct functioning of the overvoltage protector.
- Routine maintenance should include visual inspection of the SPD and monitoring of its diagnostic indicator. Either a red warning display or alarm contact activation denotes device failure requiring immediate replacement.
- Multi-unit surge suppressors in parallel configuration must maintain true parallel wiring, using minimal-length, large-gauge conductors with secure terminations and straight-line routing.
Frequently Asked Questions (FAQ)
Q1: What is the maximum discharge current (Imax) of this SPD?
The maximum discharge current (8/20μs) is up to 40kA, utilizing high-quality 34S MOV (Metal Oxide Varistor) technology.
Q2: What is the working temperature range for this device?
The operating environment temperature range is designed to withstand extreme conditions from -40°C up to +80°C.
Q3: How does the local indicator and remote alarm function work?
Under normal status, the diagnostic window shows green. If the product fails or falls, the window turns red, and the optional remote signaling contact triggers a remote alarm.
Q4: What mounting method is required for installation?
The device is designed for easy installation and configuration using a standard 35mm DIN rail mounting system.
Q5: What certifications does this surge protective device hold?
This product complies with international safety standards and holds CE, CB, RoHS, and TUV certifications.
Q6: What should I do during routine maintenance?
Routine maintenance should include visual inspections of the SPD. If you observe a red warning display or if the alarm contact activates, it indicates device failure, and the unit must be replaced immediately.