Leave Your Message
Type 2 Pluggable Surge Protection Device 1000V 2P | LKX-PV - China Suppliers Factory for High-Voltage PV Systems
Hot Products

Type 2 Pluggable Surge Protection Device 1000V 2P | LKX-PV - China Suppliers Factory for High-Voltage PV Systems

The **Type 2 SPD Surge Protective Device 20–40kA 1000V DC 2-Pole (LKX-PV)** is an essential solution for reliable Class II surge protection in **high-voltage photovoltaic and DC power systems**. This robust device effectively suppresses transient overvoltages, switching surges, and induced lightning currents, making it ideal for **China**'s growing solar energy market. Engineered with **high-energy MOV components, thermal disconnection protection, and a fast response design**, the LKX-PV ensures stable and safe operation across various applications, including **PV arrays, combiner boxes, string inverters, battery-storage systems, DC distribution panels, and off-grid or hybrid solar installations** up to 1000V DC. As one of the leading **suppliers** in the region, our **factory** is dedicated to delivering top-quality surge protection solutions that enhance the reliability and longevity of renewable energy systems

    01

    Model Meaning

    Model Meaning Diagram
    02

    Product Principle and Working Conditions

    • Meets ClassⅡ (8/20μs) SPD tests
    • Based on zinc oxide technology
    • Using 34S MOV, the maximum will be up to 8/20μs 40kA
    • No power frequency continuous flow
    • The operating environment temperature is -40°C ~ +80°C
    • Remote signaling function is optional
    • When product falls, the green window turns to red and remote signaling provides remote alarm function
    03

    Technical Parameter Details

    Parameter Specifications
    POLE 2P/2+0
    Technology MOV (Metal Oxide Varistors) GDT
    Protection mode(s) L-PE / N-PE NPE
    Nominal voltage (A.C.) [Un] 220V 300V 380V 400V 225V
    Max. continuous operating voltage (D.C.) [Ucpv] 275V 320V 385V 420V 225V
    Nominal discharge current (8/20μs) [In] 20kA 20kA
    Max. discharge current (8/20μs) [lmax] 40kA 40kA
    Protection level [Up] ≤1.5kV ≤1.6kV ≤1.8kV ≤2.0kV ≤1.5kV
    Response time [tA] ≤25ns -
    Temporary overvoltage (TOV) withstand - 5 sec [Ut] 335V 440V 440V 620V 335V
    Admissible short-circuit current [lsccr] 25kA
    Max. backup fuse 63AgL/Gg
    04

    Mechanical Data

    Parameter Mechanical Specifications
    Current AC system
    SPD configuration Single / Three phase
    Pluggable Available
    Mounting 35mm DIN rail
    Housing material Thermoplastic, UL 94 V-0
    Operating temperature -40℃ ... +80℃
    Protection rating IP20
    Remote Signaling Green / Red Indicator
    Wiring for remote signaling Optional
    Max. Voltage/Current for remote signaling Max 1.5mm² solid/flexible
    Standards compliance 250V/0.1A; 125V/0.2A; 75V/0.5A
    Certification CE, CB, RoHS, TUV
    05

    Outer Appearance and Installation Dimensions

    Dimensional Drawing 1
    Dimensional Drawing 2
    We solution have passed through the national skilled certification and been well received in our key industry. Our specialist engineering team will often be ready to serve you for consultation and feedback. We are able to also provide you with no cost samples to meet your needs. Best efforts will be produced to offer you the very best service and solutions. For anyone who is considering our business and solutions, please speak to us by sending us emails or get in touch with us right away. As a way to know our products and enterprise. lot more, you'll be able to come to our factory to find out it. We will constantly welcome guests from around the globe to our firm. o build enterprise. elations with us. Please really feel absolutely free to make contact with us for small business and we believe we will share the top trading practical experience with all our merchants.
    06

    Installation Considerations

    • 1. Prior to mounting, verify that electrical supply is isolated. Working on live equipment is absolutely forbidden.
    • 2. A protective fuse or breaker should be serially connected upstream of the lightning arrester unit.
    • 3. Refer to wiring schematics for proper installation. Positive DC connects to DC+, negative to DC-, with PE as earth ground. Prevent reverse polarity. Upon completion, activate the protection device (fuse/breaker) and confirm normal operational indicators.
    • 4. Post-installation, properly seat the component and validate correct functioning of the overvoltage protector.
    • 5. Routine maintenance should include visual inspection of the SPD and monitoring of its diagnostic indicator. Either a red warning display or alarm contact activation denotes device failure requiring immediate replacement.
    • 6. Multi-unit surge suppressors in parallel configuration must maintain true parallel wiring, using minimal-length, large-gauge conductors with secure terminations and straight-line routing.

    Frequently Asked Questions (FAQ)

    Q1: What is the maximum discharge current (Imax) of this Surge Protective Device (SPD)?

    A: The maximum discharge current (8/20μs) for this device reaches up to 40kA, utilizing 34S MOV technology.

    Q2: What do the green and red indicator windows represent?

    A: A green window indicates that the SPD is functioning normally. If the window turns red, it indicates device failure, and it must be replaced immediately. Remote signaling can also trigger an alarm.

    Q3: Under what temperature conditions can this SPD operate?

    A: The operating environment temperature range for this surge protective device is -40°C to +80°C.

    Q4: What mounting standard does the device use?

    A: The device is designed for easy installation on a standard 35mm DIN rail and features a pluggable configuration.

    Q5: Does this device support remote alarm signaling?

    A: Yes, remote signaling is optional. It provides a remote alarm function when the product falls or fails, allowing for prompt maintenance.

    Q6: What certifications does this product comply with?

    A: The product complies with major international standards and holds CE, CB, RoHS, and TUV certifications.