The **Type 2 SPD Surge Protective Device 20–40kA 1000V DC 2-Pole (LKX-PV)** is a premium solution offered by leading **China suppliers** for ensuring reliable Class II surge protection in **high-voltage photovoltaic and DC power systems**. This device effectively mitigates transient overvoltage, switching surges, and induced lightning currents, making it an essential component for the safety of your installations. Constructed with advanced **high-energy MOV components**, thermal disconnection protection, and a fast response design, it guarantees stable and safe operation for **PV arrays, combiner boxes, string inverters, battery-storage systems, DC distribution panels,** and both off-grid or hybrid solar installations up to 1000V DC. Choose our products from a trusted **factory** in China to enhance the performance and durability of your solar systems

    01

    Model Meaning

    p1j36
    02

    Product Principle and Working Conditions

    • Meets ClassⅡ (8/20μs) SPD tests
    • Based on zinc oxide technology
    • Using 34S MOV, the maximum will be up to 8/20μs 40kA
    • No power frequency continuous flow
    • The operating environment temperature is -40°C~+80°C
    • Remote signaling function is optional
    • When product falls, the green window turns to red and remote signaling provides remote alarm function
    03

    Technical Parameter Details

    POLE 2P/2+0
    Technology MOV(Metal Oxide Varistors) GDT
    Protection mode(s) L-PE/N-PE NPE
    Nominal voltage (A.C.) [Un] 220V 300V 380V 400V 225V
    Max.continuous operating voltage (D.C.) [Ucpv] 275V 320V 385V 420V 225V
    Nominal discharge current(8/20μs) [In] 20kA 20kA
    Max.discharge current (8/20μs) [lmax] 40kA 40kA
    Protection level [Up] ≤1.5kV ≤1.6kV ≤1.8kV ≤2.0kV ≤1.5kV
    Response time [tA] ≤25ns  
    Temporary overvoltage(TOV) withstand - 5 sec [Ut] 335V 440V 440V 620V 335V
    Admissible short-circuit current [lsccr] 25kA
    Max. backup fuse 63AgL/Gg
    04

    Mechanical Data

    Mechanical Data
    Current AC system
    SPD configuration Single/Three phase
    Pluggable Available
    Mounting 35mm DIN rail
    Housing material Thermoplastic, UL 94 V-0
    Operating temperature -40℃...+80℃
    Protection rating IP20
    Remote Signaling Green/Red
    Wiring for remote signaling Optional
    Max.Voltage/Current for remote signaling Max 1.5mm solid/flexible
    Standards compliance 250V/0.1A; 125V/0.2A; 75V/0.5A
    Certification CE, CB, RoHS, TUV
    05

    Outer Appearance and Installation Dimensions

    4hsh
    570h
    We solution have passed through the national skilled certification and been well received in our key industry. Our specialist engineering team will often be ready to serve you for consultation and feedback. We are able to also provide you with no cost samples to meet your needs. Best efforts will be produced to offer you the very best service and solutions. For anyone who is considering our business and solutions, please speak to us by sending us emails or get in touch with us right away. As a way to know our products and enterprise. lot more, you'll be able to come to our factory to find out it. We will constantly welcome guests from around the globe to our firm. o build enterprise. elations with us. Please really feel absolutely free to make contact with us for small business and we believe we will share the top trading practical experience with all our merchants.
    06

    Installation Considerations

    • 1 Prior to mounting, verify that electrical supply is isolated. Working on live equipment is absolutely forbidden.
    • 2 A protective fuse or breaker should be serially connected upstream of the lightning arrester unit.
    • 3 Refer to wiring schematics for proper installation. Positive DC connects to DC+, negative to DC-, with PE as earth ground. Prevent reverse polarity. Upon completion, activate the protection device (fuse/breaker) and confirm normal operational indicators.
    • 4 Post-installation, properly seat the component and validate correct functioning of the overvoltage protector.
    • 5 Routine maintenance should include visual inspection of the SPD and monitoring of its diagnostic indicator. Either a red warning display or alarm contact activation denotes device failure requiring immediate replacement.
    • 6 Multi-unit surge suppressors in parallel configuration must maintain true parallel wiring, using minimal-length, large-gauge conductors with secure terminations and straight-line routing.

    Frequently Asked Questions (FAQ)

    Q1: What is the operating temperature range for this surge protective device (SPD)?

    A: The operating environment temperature for this device is designed to function reliably from -40°C to +80°C.

    Q2: How does the visual failure indicator work on this SPD?

    A: The device features a diagnostic window. Under normal operation, it displays green. If the product falls or fails, the window turns red, and an optional remote signaling function can trigger a remote alarm.

    Q3: What core technology is used in this surge protector?

    A: This SPD is based on zinc oxide technology utilizing 34S Metal Oxide Varistors (MOV) and Gas Discharge Tubes (GDT) to meet Class II (8/20μs) test standards.

    Q4: What mounting method is required for installation?

    A: The unit is designed for standard DIN rail mounting on a 35mm DIN rail, making it compatible with standard electrical enclosures.

    Q5: What safety precautions must be taken during installation?

    A: Before mounting, you must isolate the electrical supply. Working on live equipment is strictly forbidden. Additionally, a protective fuse or breaker must be connected upstream of the unit, and correct wiring polarity must be maintained.

    Q6: What certifications does this SPD comply with?

    A: The device is fully compliant with international safety and quality standards, holding CE, CB, RoHS, and TUV certifications.