Transient Voltage Surge Suppressor 275V 2P Type 2| LKX-C40
Type 2 Surge Protection

Transient Voltage Surge Suppressor 275V 2P Type 2| LKX-C40

The Type 2 SPD Surge Protective Device 20–40kA 275V AC 2-Pole (LKX-C40) delivers reliable Class II surge protection for low-voltage power systems, effectively suppressing transient overvoltage, switching surges, and indirect lightning currents. Built with high-performance MOV technology, it offers fast response, stable operation, and durable protection for residential distribution boards, commercial power panels, HVAC equipment, industrial control systems, and general AC circuits.

    01

    Product principle and working conditions

    1.Meets Class Ⅱ (8/20μs) SPD tests
    2. Based on zinc oxide technology
    3. Using 34S MOV,the maximum will be up to 8/20μs 40kA
    4. No power frequency continuous flow
    5. Compact,yet high surge rated pluggable design, using minimum 35mm DIN rail width
    6.The operating environment temperature is -40℃~+80℃
    7.Red/Green status indication and change-over contacts standard for remote monitoring.(Remote function is option)

    02

    Technical parameter details

    Technical Data
    POLE 2P/2+0
    Technology MOV(Metal Oxide Varistors) GDT
    Protection mode(s) L-PE/N-PE NPE
    Nominal voltage (A.C.)   [Un] 220V 300V 380V 400V 225V
    Max.continuous operating voltage (D.C.) [Ucpv] 275V 320V 385V 420V 225V
    Nominal discharge current(8/20μs)   [In] 20kA 20kA
    Max.discharge current (8/20μs)  [lmax] 40kA 40kA
    Protection level  [Up] ≤1.5kV ≤1.6kV ≤1.8kV ≤2.0kV ≤1.5kV
    Response time  [tA] ≤25ns  
    Temporary overvoltage(TOV) withstand - 5 sec   [Ut] 335V 440V 440V 620V 335V
    Admissible short-circuit current  [lsccr] 25kA
    Max, backup fuse 63AgL/Gg
    03

    Mechanical Data

    Mechanical Data
    Current AC system
    SPD configuration Single/Three phase
    Pluggable Available
    Mounting 35mm DlN rail
    Housing material Thermoplastic,UL 94 V-O
    Operating temperature -40℃...+80℃
    Protection rating IP20
    Remote Signaling Green/Red
    Wiring for remote signaling Optional
    Max.Voltage/Current for remote signaling Max 1.5mm solid/flexible
    Standards compliance 250V/0.1A;125V/0.2A;75V/0.5A
    Certification CE, CB, RoHS,TUV
    04

    Outer appearance and installation dimensions

    Type 2 SPD surge protective device 20kA-40kA 275V 2P AC outer appearanceType 2 SPD 275V 2P surge protective device installation dimensions diagram
    05

    Installation considerations

    1. Make sure the electricity is turned off before installation. It is completely forbidden to operate when electrified.
    2. It is advised to connect a circuit breaker or fuse in series with the surge protection module's front end.
    3. During installation, adhere to the installation schematic for connection. Steer clear of bad connections. Close the circuit breaker (or fuse) switch after installation, then make sure everything is operating normally.
    4. After installation, make sure the surge protection module is operating properly by putting it in place.
    5. Check the condition of the fault display window and conduct routine inspections of the surge protection module while in use. The surge protection module needs to be changed or repaired right away if the fault display window turns red or if the remote signaling terminal emits an alert signal.
     6. It is recommended to install parallel-connected power surge protection devices. The connection wires need to be straight, short, thick, dependable, and secure.